Items |
/Asset/IFC_242x_18x13.jpg IFC2421 24 Volt (V) Direct Current Supply Voltage confocalDT 2421 Controller for Distance or Thickness Measurement |
/Asset/IFC_242x_18x13.jpg IFC2421MP 24 Volt (V) Direct Current Supply Voltage confocalDT 2421 Controller for Distance or Thickness Measurement |
/Asset/IFC_242x_18x13.jpg IFC2422 24 Volt (V) Direct Current Supply Voltage confocalDT 2422 Controller for Distance or Thickness Measurement |
/Asset/IFC_242x_18x13.jpg IFC2422MP 24 Volt (V) Direct Current Supply Voltage confocalDT 2422 Controller for Distance or Thickness Measurement |
||||
Description |
N/A
The confocalDT 2421 and 2422 controllers set a new standard in the industry when it comes to high precision, confocal measurement technology. Available as either a single- or a dual-channel version, these measurement systems enable a low cost solution especially for high volume applications. The active exposure regulation feature in the CCD array enables accurate, fast surface compensation on difficult changing surfaces. |
|||||||
Multi Peak Measurement | N/A 2 Peaks | N/A 6 Peaks | N/A 2 Peaks | N/A 6 Peaks | ||||
Measurement Channels | N/A 1 | N/A 1 | N/A 2 | N/A 2 | ||||
Light Source | N/A Internal White Light-Emitting Diode (LED) | |||||||
Measuring Rate1 | N/A 100 Hz to 6.5 kHz | |||||||
Ethernet/EtherCAT Resolution | N/A 1 nm | |||||||
RS422 Resolution | N/A 18 bits | |||||||
Analog Resolution | N/A 16 bits | |||||||
Storage2 | N/A Up to 20 | |||||||
Controller Input/Output (I/O) | N/A Analog: Current, Voltage (16 bit D/A Converter) Encoder (2x A, A, B, Index) Error1-Out, Error2-Out EtherCAT/Ethernet RS422 Sync-In/Trigger-In, Sync-Out | |||||||
Type | N/A EtherCAT | |||||||
Operating Elements | N/A Multifunction button (As well as Dark Alignment and Reset to Factory Setting after 10 sec) | |||||||
Controller Display | N/A 5x LED for intensity, range, status, supply voltage | |||||||
Direct Current (DC) Supply Voltage | N/A 24 V | |||||||
Direct Current (DC) Supply Voltage Tolerance (±) | N/A 15 % | |||||||
Approximate Power Consumption | N/A 10 W | |||||||
Housing | N/A Aluminum case for DIN rail mounting | |||||||
Protection Class | N/A Ingress Protection (IP40) | |||||||
Operating Temperature | N/A 5 to 50 ºC | |||||||
Storage Temperature | N/A -20 to 70 ºC | |||||||
Permissible Ambient Light | N/A 30,000 lux | |||||||
Safety | N/A CE | |||||||
Electromagnetic Compatibility (EMC) Interference Emission | N/A EN 61 000-6-3/DIN EN 61326-1 (class B) | |||||||
Interference Resistance | N/A EN 61 000-6-2/DIN EN 61326-1 | |||||||
Shock Amplitude | N/A 15 g. | |||||||
Shock Duration | N/A 6 ms | |||||||
Vibration Amplitude | N/A 2 g. | |||||||
Vibration Frequency Range | N/A 10 to 500 Hz | |||||||
Length of Optical Fiber/Sensor Cable | N/A 2 to 50 m | |||||||
Connector | N/A E2000 | |||||||
EtherCAT Cable | N/A CAT5E | |||||||
Ethernet Cable Length | N/A < 100 m | |||||||
Maximum Supply Cable Length (RS422, Sync./Error) | N/A < 30 m | |||||||
Maximum Analog Cable Length | N/A < 30 m | |||||||
Maximum Encoder Cable Length | N/A < 3 m | |||||||
Note for Maximum Cable Lengths | N/A All cables are Shielded | |||||||
Interfaces | N/A Analogue EtherCAT Ethernet RS422 | |||||||
Overall Height | N/A 123.8 mm | |||||||
Overall Length | N/A 218 mm | N/A 218 mm | N/A 239 mm | N/A 239 mm | ||||
Features |
N/A
Fast surface compensation Configuration via web interface Submicrometer resolution Multilayer thickness measurement Synchronous two-sided thickness measurement Robust design with passive cooling |
|||||||
Additional Information |
N/A
The controller can be operated with any IFS sensor and is available as a standard version for distance measurements or as a multi-peak version for multilayer thickness measurements. Using a special calculation function, the confocalDT 2422 dual-channel version evaluates both channels.Measurement acquisition is synchronous and can be carried out while exploiting the full measuring rate for both channels. Due to a user-friendly web interface, the entire configuration process is carried out without using any additional software. Data output is via Ethernet, EtherCAT, RS422 or analogue output. The new, confocal industry standard All settings are performed in the web interface. Materials are stored in an expandable materials database. Two sensors can be directly connected to the confocal controller. |
|||||||
|