COMPANY HEADER
Request Information
The transmission sensor ACS3 is used to measure self-luminous and transparent objects like foil, glass and Plexiglas. For the color measurement of self-luminous objects, only a receiver unit is required. Measuring transparent objects requires transmitter (TT) and receiver unit (TR) which can be installed with a mounting set.
Unit of Measure

Specifications

Model

N/A colorCONTROL ACS3

Article Number

N/A 10824412

Measurement Geometry (Illumination/Receiver)

N/A Receiver

Measurement Spot Diameter

N/A 9 mm for < 200 mm

Optimal Measurement Distance

N/A 10 to 200 mm

Permissible Measurement Distance

N/A 10 to 300 mm

Distance Tolerance

N/A <0.005 ΔE/mm <0.01 ΔE/mm

Tilt Angular Tolerance

N/A <0.05 ΔE/º

Ambient Light Tolerance at Maximum LED-Performance

N/A <0.05 ΔE/1000 lux

Lens Diameter

N/A 22 x 40 mm

Weight (Sensor Including Optical Fiber)

N/A 70 g

Length of Optical Fiber/Sensor Cable

N/A 1.2 m

Maximum Length of Optical Fiber/Sensor Cable

N/A 30 m

Bending Radius Sensor Cable

N/A 70 mm

Protection Class

N/A Ingress Protection (IP64)

Operating Temperature

N/A -20 to +70 ºC

Storage Temperature

N/A -20 to 70 ºC

Shock

Shock Amplitude

N/A 15 g.

Shock Duration

N/A 6 ms

Note for Shock

N/A According to DIN EN 60068-2-29

Vibration

Vibration Amplitude

N/A 2 g.

Vibration Frequency Range

N/A 10 to 500 Hz

Note for Vibration

N/A According to DIN EN 60068-2-6

Features

N/A

  • Measurement of self-luminous and transparent objects
  • Measurement distance: maximum 300mm
  • Measurement geometry: transmission
  • Measurement spot: Ø5/Ø9 mm (at a measurement distance up to 200 mm)

Note

N/A For Measurement Spot Diameter:

  • Measurement spot diverges with growing distance between receiver and target
For Optimal Measurement Distance & Permissible Measurement Distance:
  • Valid in combination with ACS3-TT15-200 for the transmission measurement (transmitted light)
  • When measuring the transmission, the "optimal measurement distance" and the "permissible measurement distance" refer to the distance between transmitter and receiver.
    The sample can be at any position within the light curtain between transmitter and receiver.
For Distance Tolerance & Tilt Angular Tolerance:
  • <0.01 ΔE/mm: When using it as receiver sensor for illumination measurement
  • <0.005 ΔE/mm: Valid in combination with ACS3-TT15-200 for the transmission measurement (transmitted light)
  • Tilt angular tolerance and distance tolerance were determined in transmission with different color glass filters (thickness 2.5 mm, refraction index 1.5).
    When measuring the illumination (only receiver), these were determined with uniformly illuminated (Lambertian) diffuser by tilting the transmitter towards the receiver.