COMPANY HEADER
Request Information
The confocalDT 2471 HS controllers are used for fast distance and thickness measurements of highly reflecting surfaces. The controllers are equipped with enhanced optical components enabling measuring rates up to 70kHz without having to use an external light source. The confocalDT HS controllers are considered one of the fastest confocal measurement systems in the world. The active exposure regulation feature in the CCD array enables accurate, fast surface compensation on difficult changing surfaces during dynamic measurement processes.
Unit of Measure

Specifications

Multi Peak Measurement

N/A 2 Peaks

Light Source

N/A Internal White Light-Emitting Diode (LED)

Continuously Adjustable Measuring Rate

N/A 100 Hz to 70 kHz

Ethernet/EtherCAT Resolution

N/A 1 nm

RS422 Resolution

N/A 18 bits

Analog Resolution

N/A 16 bits
Storage1 N/A Up to 20

Controller Input/Output (I/O)

N/A Analog: Current, Voltage (16 bit D/A Converter) Encoder (2x A, A, B, Index) Error1-Out, Error2-Out EtherCAT/Ethernet RS422 Sync-In/Trigger-In, Sync-Out

Operating Elements

N/A Button for Dark Alignment (As well as for Reset to Factory Setting after 10 sec) On/Off Switch

Controller Display

N/A 4x Light-Emitting Diode (LED) for Intensity, Range, Status, Supply Voltage

Direct Current (DC) Supply Voltage (± 15 Percent (%))

N/A 24 V

Tolerance for Direct Current (DC) Supply Voltage (±)

N/A 15 %

Power Consumption

N/A ~ 10 W

Housing Material for DIN Rail Mounting

N/A Aluminum

Protection Class

N/A Ingress Protection (IP40)

Operating Temperature

N/A 5 to 50 ºC

Storage Temperature

N/A -20 to 70 ºC

Permissible Ambient Light

N/A 30,000 lux

Safety

Electromagnetic Compatibility (EMC) Requirements

N/A CE

Interference Emission

N/A EN 61 000-6-3/DIN EN 61326-1 (Class B)

Interference Resistance

N/A EN 61 000-6-2/DIN EN 61326-1

Shock

Shock Amplitude

N/A 15 g.

Shock Duration

N/A 6 ms

Vibration

Vibration Amplitude

N/A 2 g.

Vibration Frequency Range

N/A 10 to 500 Hz

Optical Fiber Information

Sensor Cable Length

N/A 2 to 50 m

Connector

N/A E2000

Cable Information

EtherCAT Cable

N/A CAT5E

Ethernet Cable Length

N/A < 100 m

Supply Cable Length (Sync./Error)

N/A < 30 m

Analog Cable Length

N/A < 30 m

Encoder Cable Length

N/A < 3 m

Note for Cable Information

N/A All Cables are Shielded

Features

Features

N/A
  • Fastest controller worldwide: Measuring rate up to 70kHz
  • Interfaces: Ethernet / EtherCAT / RS422 / Analogue
  • Fast surface compensation
  • Configuration via web interface
  • Sub micrometer resolution
  • Multilayer thickness measurement
  • Robust design with passive cooling

Additional Information

Additional Information

N/A The controller can be operated with any IFS sensor and is available as a standard version for distance measurements or as a multi-peak version for thickness measurements.

Due to a user-friendly web interface, the entire configuration process is carried out without using any additional software. Data output is via Ethernet, EtherCAT, RS422 or analogue output.
  • 1 Calibration tables for different sensors, menu selection