Static Resolution at 20 Hertz (Hz) Full Scale Output (FSO)1 | N/A 0.005 % |
Dynamic Resolution at 20 Kilohertz (kHz) Full Scale Output (FSO)2 | N/A 0.025 % |
Frequency Response at -3 Decibel (dB)3 | N/A 5 kHz20 kHz20 Hz |
Measuring Rate |
N/A 50 kSa/s |
Linearity Full Scale Output (FSO)4 | N/A <±0.1 % |
Temperature Compensation Range |
N/A 10 to 50 ºC |
Synchronization |
N/A With LF and HF Variants |
Target Material5 | N/A Aluminum Steel |
Maximum Number of Characteristic Curves |
N/A 4 |
Direct Current (DC) Supply Voltage |
N/A 12 to 32 V |
Power Consumption |
N/A 2.5 W |
Digital Interface |
N/A Industrial Ethernet |
Analog Output Current |
N/A 4 to 20 mA |
Analog Output Voltage |
N/A 0 to 10 V |
Note for Analog Output |
N/A Short Circuit Proof |
Connection |
N/A Industrial Ethernet: 5-pole M12 connector Sensor: plug connector triaxial socket Supply/signal: 8-pole M12 connector |
Mounting |
N/A Through Bores |
Storage Temperature Range |
N/A -10 to 70 ºC |
Operation Temperature Range |
N/A 0 to 50 ºC |
Shock (DIN-EN 60068-2-27) |
N/A 15 g6 ms in 3 axes, 2 directions and 1000 shocks each ms |
Vibration (DIN-EN 60068-2-6) |
N/A 5 g10 to 500 Hz in 3 axes, 2 directions and 10 cycles each |
Protection Class (DIN-EN 60529) |
N/A Ingress Protection (IP67) (Plugged) |
Material |
N/A Die-Cast Aluminum |
Approximate Weight |
N/A 230 g |
Characteristics |
N/A
|
N/A
Performance and universality for industrial use |
Features |
N/A
|
N/A
For operating several eddyNCDT measuring systems, a new frequency separation (LF/HF) is provided. The frequency separation enables multi-channel operation without mutual influence. This function makes a synchronization cable superfluous. |