Measuring Range |
N/A 2 mm |
Approximate Start of Measuring Range |
N/A 9.6 mm |
Note for Approximate Start of Measuring Range |
N/A Start of measuring range measured from sensor axis. |
Static Resolution1 | N/A 40 nm |
Display Resolution2 | N/A 125 nm |
Displacement and Distance Linearity3 | N/A <±1 µm |
Thickness Linearity4 | N/A <±2 µm |
Light Spot Diameter |
N/A 10 µm |
Maximum Tilt Angle5 | N/A ±12 º |
Numerical Aperture (NA) |
N/A 0.25 |
Minimum Target Thickness6 | N/A 0.1 µm |
Connection |
N/A Pluggable optical fiber via FC socket, type C2404-x; Standard length 2 m; Extension up to 50 m; Bending radius: static 30 mm, dynamic 40 mm |
Installation |
N/A Clamping Mounting Adapter |
Storage Temperature Range |
N/A -20 to 70 ºC |
Operation Temperature Range |
N/A 5 to 70 ºC |
Shock (DIN-EN 60068-2-27) |
N/A 15 g6 ms in XY axis, 1000 shocks each |
Vibration (DIN-EN 60068-2-6) |
N/A 20 g20 to 500 Hz in XY axis, 10 cycles each |
Protection Class (DIN-EN 60529) |
N/A Ingress Protection (IP65) (Front) |
Material |
N/A Glass Lenses |
Housing Material |
N/A Stainless Steel |
Approximate Weight |
N/A 30 g |
System Design |
N/A
The confocalDT system consists of:
|
Customer-Specific Modifications |
N/A
Application examples are often found where the standard versions of the sensors and the controllers are performing at their limits. To facilitate such special tasks, it is possible to customize the sensor design and to adjust the controller accordingly. Common requests for modifications include changes in design, mounting options, customized cable lengths and modified measuring ranges.Possible modifications
|