Items |
TIM M1 thermoIMAGER TIM M1 Thermal Imaging Camera for Hot Metal Surfaces |
TIM M-1-N1064 thermoIMAGER TIM M-1-N1064 Thermal Imaging Camera for Hot Metal Surfaces |
TIM M-1-B880 thermoIMAGER TIM M-1-B880 Thermal Imaging Camera for Hot Metal Surfaces |
|||
Description |
N/A
Short wavelength infrared camera for high temperature measurements of metal surfaces
|
N/A
Special model with laser blocking filter at wavelength of 1064 nm (focal length of only 16 mm and 25 mm)
|
N/A
Special model with blocking filter from 1000 nm to 1200 nm (focal length of only 25 mm)
|
|||
Optical Resolution at 32 Hertz (Hz) Frequency | N/A 764 x 480 px | |||||
Optical Resolution at 80 Hertz (Hz) Frequency1 | N/A 382 x 288 px | N/A | N/A | |||
Optical Resolution at 80 Hertz (Hz) Frequency (Switchable to 27 Hz) | N/A 382 x 288 px | |||||
Optical Resolution at 1 Kilohertz (kHz) Frequency | N/A 72 x 56 px | |||||
Optical Resolution at 1 Kilohertz (kHz) Frequency (Fast Line-Scan Mode) | N/A 764 x 8 px | |||||
Temperature Range at 27 Hertz (Hz) Modes | N/A 450 to 1800 ºC | N/A 450 to 1800 ºC | N/A 525 to 1800 ºC | |||
Temperature Range at 32 and 27 Hertz (Hz) Modes | N/A 450 to 1800 ºC | N/A | N/A | |||
Temperature Range at 32 Hertz (Hz) Modes | N/A | N/A 500 to 1800 ºC | N/A 600 to 1800 ºC | |||
Temperature Range at 80 Hertz (Hz) Modes | N/A 500 to 1800 ºC | N/A 500 to 1800 ºC | N/A 550 to 1800 ºC | |||
Temperature Range at 80 and 32 Hertz (Hz) Modes | N/A 500 to 1800 ºC | N/A | N/A | |||
Temperature Range at 1 Kilohertz (kHz) Modes | N/A 600 to 1800 ºC | N/A 700 to 1800 ºC | N/A 625 to 1800 ºC | |||
Note for Temperature Range | N/A | N/A +75 ºC higher initial temperature with lenses providing a focal length of f = 50 mm and f =75 mm | N/A +75 ºC higher initial temperature with lenses providing a focal length of f = 50 mm and f = 75 mm | |||
Spectral Range | N/A 0.85 to 1.1 µm | N/A 0.92 to 1.1 µm | N/A 0.92 to 1.1 µm | |||
Note for Spectral Range | N/A | N/A With blocking filter at 1064 nm / FWHM = 44 nm |
N/A
With blocking filter at 1000-1200 nm Bandpass filter: CWL = 880 ± 8 nm, FWHM = 70 ± 8 nm |
|||
Frame Rate2 | N/A Up to 1 kHz | |||||
System Accuracy (±) | N/A 1 % of Reading | |||||
Object Temperature System Accuracy | N/A < 1400 ºC | |||||
Lens Field of View (FOV) at 764 x 480 Pixel (px) for f = 16 Millimeter (mm) | N/A 39 x 25 º | N/A | N/A | |||
Lens Field of View (FOV) at 764 x 480 Pixel (px) for f = 25 Millimeter (mm) | N/A 26 x 16 º | |||||
Lens Field of View (FOV) at 764 x 480 Pixel (px) for f = 50 Millimeter (mm) | N/A 13 x 8 º | N/A | N/A | |||
Lens Field of View (FOV) at 764 x 480 Pixel (px) for f = 75 Millimeter (mm) | N/A 9 x 5 º | N/A | N/A | |||
Lens Field of View (FOV) at 382 x 288 Pixel (px) for f = 16 Millimeter (mm) | N/A 20 x 15 º | N/A | N/A | |||
Lens Field of View (FOV) at 382 x 288 Pixel (px) for f = 25 Millimeter (mm) | N/A 13 x 10 º | |||||
Lens Field of View (FOV) at 382 x 288 Pixel (px) for f = 50 Millimeter (mm) | N/A 7 x 5 º | N/A | N/A | |||
Lens Field of View (FOV) at 382 x 288 Pixel (px) for f = 75 Millimeter (mm) | N/A 4 x 3 º | N/A | N/A | |||
Note for Lens Field of View (FOV) | N/A | N/A Measurement accuracy can be out of specification with distances below 500 mm | N/A Measurement accuracy can be out of specification with distances below 500 mm | |||
Thermal Sensitivity (NETD) | N/A <1 K<2 K1000 ºC700 ºC | N/A <1 K <2 K 1000 ºC 700 ºC | N/A <1 K <2 K 1000 ºC 700 ºC | |||
Detector | N/A CMOS | |||||
Detector Size | N/A 15 x 15 µm | |||||
Digital Output | N/A Optional GigE USB 2.0 | |||||
Standard Process Interface (PIF) | N/A 0 to 10 V Input 0 to 10 V Output Digital Input (Maximum 24 V) | |||||
Industry Process Interface (PIF) | N/A 2x 0 to 10 V Input 3x 0 to 10V Output 3x Relays (0 - 30V/ 400mA) Digital Input (Maximum 24 V) Fail Safe Relay | N/A 2x 0 to 10 V Input 3x 0(4) - 20 mA outputs 3x Relays (0 - 30V/ 400mA) Digital Input (Maximum 24 V) Fail Safe Relay | N/A 2x 0 to 10 V Input 3x 0(4) - 20 mA outputs 3x Relays (0 - 30V/ 400mA) Digital Input (Maximum 24 V) Fail Safe Relay | |||
Standard Universal Serial Bus (USB) Cable Length | N/A 1 m | |||||
Universal Serial Bus (USB) Cable Length3 | N/A 10 m5 m | |||||
Power Supply | N/A USB Powered | |||||
Tripod Mount | N/A 1/4 in. - 20 UNC | |||||
Protection Class | N/A Ingress Protection (IP67) | |||||
Ambient Temperature | N/A 0 to 50 ºC5 to 50 ºC | N/A 0 to 50 ºC | N/A 5 to 50 ºC | |||
Storage Temperature | N/A -40 to 70 ºC | |||||
Non-Condensing Relative Humidity | N/A 20 to 80 % | |||||
Vibration | N/A IEC 60068-2-6 (sinus-shaped) IEC 60068-2-64 (broadband noise) | |||||
Shock Amplitude | N/A 25 g.50 g. | |||||
Note for Shock | N/A According to IEC 60068-2-27 | |||||
Housing Dimensions | N/A 46 x 56 x 90 mm | |||||
Weight Including Lens | N/A 320 g | |||||
Depth | N/A 6 mm | N/A | N/A | |||
Diameter | N/A 43 mm | N/A | N/A | |||
PC Requirements | N/A 1 GB RAM Minimum 1.5 GHz Windows 7 Windows XP SP 2 | N/A 1 GB RAM Minimum 1.5 GHz Windows 7 and 10 Windows XP SP 2 | N/A 1 GB RAM Minimum 1.5 GHz Windows 7 and 10 Windows XP SP 2 | |||
Scope of Supply |
N/A
|
|||||
Software |
N/A
|
|||||
|