Measurement Range |
N/A 5000 mm |
Analog Output |
N/A Current Potentiometer Voltage |
Resolution |
N/A Towards Infinity |
Linearity ≤ 0.25% Full Scale Output (FSO) |
N/A ≤±12.5 mm |
Sensor Element |
N/A Hybrid Potentiometer |
Approximate Maximum Wire Extension Force |
N/A 8 N |
Approximate Minimum Wire Retraction Force |
N/A 2 N |
Approximate Maximum Wire Acceleration |
N/A 5 g. |
Housing Material |
N/A Glass-Fiber Reinforced Plastic |
Measuring Wire Diameter |
N/A 0.61 mm |
Measuring Wire Material |
N/A Polyamide-Coated Stainless Steel |
Wire Mounting |
N/A Wire Clip |
Mounting |
N/A Through-Bores ø 6.4 mm and Mounting Nuts (for M6) on the Sensor Housing |
Storage Temperature Range |
N/A -40 to 85 ºC |
Operation Temperature Range |
N/A -40 to 85 ºC |
Connection |
N/A Integrated Cable, Radial, Length 1 m |
Shock (DIN-EN 60068-2-27) |
N/A 50 g5 ms in 3 axes, 2 directions and 1000 shocks each |
Vibration (DIN-EN 60068-2-6) |
N/A 20 g20 to 2000 Hz in 3 axes and 10 cycles each |
Protection Class (DIN-EN 60529) |
N/A Ingress Protection (IP69K) |
Approximate Weight |
N/A 500 g |
Characteristics |
N/A
|
Installation Instructions |
N/A
Wire attachment: during installation, do not allow at any time the measuring wire to freely return. Angle of wire outlet: Make sure during installation that the wire outlet is straight (tolerance of ±3º). Exceeding this tolerance leads to increased wear of the wire material and on the wire outlet. |