COMPANY HEADER
Print Back
The thermoIMAGER TIM M-08 thermal imaging camera is designed for non-contact temperature measurements during laser processing. In addition to the well-known advantages of thermoIMAGER infrared cameras such as their compact size, USB interface and license-free software, the TIM M-08 camera can be continuously used in a temperature range from 575 ºC to 1900 ºC without any interruptions. Therefore, this camera offers a high degree of flexibility as it is not necessary to switch the measuring range.

The special narrow-band spectral sensitivity at 800 nm makes the short-wavelength infrared camera ideal for almost all NIR and CO2 laser processing applications.
Unit of Measure

Specifications

Spectral Range

N/A 780 to 820 nm

Frame Rate

N/A Up to 1 kHz

Note for Frame Rate

N/A 1 ms real-time analog output (0 - 10 V) from 8 x 8 pixels (freely selectable).

System Accuracy

N/A ±1 % of Reading ±5 % of Reading Object Temperature <1500 ºCObject Temperature >1500 ºC

Detector

N/A CMOS (15 µm x 15 µm)

Digital Output

N/A USB 2.0/Optional GigE

Standard Process Interface (PIF)

N/A 0 - 10 V input 0 - 10 V output digital input (max. 24 V)

Industry Process Interface (PIF)

N/A 2x 0 - 10 V inputs 3x 0(4) - 20 mA outputs 3x relays (0 - 30 V / 400 mA) digital input (max. 24 V) fail-safe relay

Standard Cable Length

N/A 1 m

Cable Length

N/A 10 m5 m

Note for Cable Length

N/A 5 m and 10 m also available as high temperature USB cable (180 ºC or 250 ºC)

Power Supply

N/A USB Powered

Tripod Mount

N/A 1/4 in. - 20 UNC
Protection Class1 N/A Ingress Protection (IP67)

Ambient Temperature

N/A 5 to 50 ºC

Storage Temperature

N/A -40 to 70 ºC

Non-Condensing Relative Humidity

N/A 20 to 80 %

Vibration

N/A IEC 60068-2-6 (sinus-shaped) IEC 60068-2-64 (broadband noise)

Shock Amplitude

N/A 25 g.50 g.

Note for Shock

N/A According to IEC 60068-2-27

For more information see operating instructions.

Housing Size

N/A 46 x 56 x 88 to 129 mm

Note for Housing Size

N/A Depending on lens and focus position.

Weight Including Lens

N/A 245 to 311 g

Optical Resolution

Optical Resolution at 32 Hertz (Hz) Frequency

N/A 764 x 480 px

Optical Resolution at 1 Kilohertz (kHz) Frequency

N/A 72 x 56 px

Optical Resolution at 80 Hertz (Hz) Frequency (Switchable to 27 Hz)

N/A 382 x 288 px

Optical Resolution at 1 Kilohertz (kHz) Frequency (Fast Line-Scan Mode)

N/A 764 x 8 px

Temperature Range

Temperature Range at 27 Hertz (Hz) Modes

N/A 575 to 1900 ºC

Temperature Range at 32 Hertz (Hz) Modes

N/A 625 to 1900 ºC

Temperature Range at 80 Hertz (Hz) Modes

N/A 625 to 1900 ºC

Temperature Range at 1 Kilohertz (kHz) Modes

N/A 750 to 1900 ºC

Lenses

Lens Field of View (FOV) at 764 x 480 Pixel (px) for f = 25 Millimeter (mm)

N/A 26 x 16 º

Lens Field of View (FOV) at 382 x 288 Pixel (px) for f = 25 Millimeter (mm)

N/A 13 x 10 º

Thermal Sensitivity (NETD)

Thermal Sensitivity (NETD)

N/A 27 Hz to 1 kHz mK<2 K<1000 ºC

Scope of Supply

Scope of Supply

N/A
  • TIM process camera incl. a selectable lens
  • Lens cap incl. protective window
  • Operating instructions
  • USB cable 1 m
  • Software for real-time processing and analyzing thermal images
  • Tripod mount
  • PIF cable incl. terminal block (1 m)
  • Transport case
  • Optional: Cooling Jacket Advanced, high temperature cable

Software Features

Software Features

N/A Comprehensive IR camera software
  • License-free analysis software and complete SDK included
  • Intuitive user interface
  • Camera remote control via software
  • Displays several camera images in different windows
  • Compatible with Windows 7, 8 and 10
  • Data output via PIF hardware interface using up to 3 analog channels
Video recording and snapshot feature (IR)
  • Recording of video sequences and individual images for later analysis or documentation
  • Adjustable frame rate to reduce data volume
  • Display of snapshot process for direct analysis
Online and offline data analysis
  • Real-time temperature information (ºC or ºF) in main window, as digital display or graphic display
  • Detailed analysis using measuring fields, automatic hotspot/coldspot search
  • Logical linking of temperature information
  • Slow-motion replay without connected camera
  • Various layout functions and color palettes to highlight thermal contrasts
Temperature data analysis and documentation
  • Triggered data collection
  • Radiometric video sequences (*.ravi) and snapshots (*.tiff)
  • Thermal images as *.tiff or *.csv, *.dat text files incl. complete temperature information
  • Data transfer in real time to other software programs via DLL or COM port interfaces

Additional Information

Additional Information

N/A The powerful sensor electronics not only enable process thermography but also the output of temperature data of the center pixel at 1kHz and so can also be used as a pyrometer. The TIM M-1 thermal imaging camera is primarily used for temperature monitoring of hardening and forming processes for hot metals but also for processing graphite and ceramics.

Special narrow-band spectral sensitivity with 800 nm
Ideal for almost all NIR and CO2 laser processing applications

  • 1 Only applies when lens protection tube is used