COMPANY HEADER
Print Back
The thermoIMAGER TIM QVGA and TIM 640 cameras are used for stationary thermography tasks where high resolution is required. Due to their high thermal sensitivity, these cameras also detect even the smallest of temperature differences. Both standard lenses and special microscope lenses are available for the TIM QVGA and TIM 640 cameras. The microscope lens enables detailed macro shooting of the smallest of elements. High-resolution macro shooting is possible with a spatial resolution of 28 µm. The distance between the target and the camera varies between 80 mm and 100 mm.
Unit of Measure

Specifications

Spectral Range

N/A 8 to 14 µm

Frame Rate

N/A 27 Hz80 Hz

Note for Frame Rate

N/A Switchable

System Accuracy

N/A ±2 ºC or ±2 %, Whichever is Greater

Note for System Accuracy

N/A TIM QVGA-HD-T100: ±0.5 °C with ambient reference radiator TM-BR20AR-TIM.

Detector

N/A Focal Plane Array (FPA) - Uncooled micro bolometer (17 x 17 µm2)

Digital Output

N/A Optional interface USB to GigE (PoE) USB 2.0

Standard Process Interface (PIF)

N/A 0 - 10 V input 0 - 10 V output digital input (max. 24 V)

Industry Process Interface (PIF)

N/A 2x 0 - 10 V inputs 3x 0/4 - 20 mA Outputs 3x Relays (0 - 30 V/ 400 mA) digital input (max. 24 V) fail-safe relay

Standard Cable Length

N/A 1 m

Cable Length

N/A 10 m20 m5 m

Note for Cable Length

N/A 5 m and 10 m also available as high temperature USB cable (180 ºC or 250 ºC).

Power Supply

N/A USB Powered

Tripod Mount

N/A 1/4 in. - 20 UNC
Protection Class1 N/A Ingress Protection (IP67)

Ambient Temperature

N/A 0 to 70 ºC

Storage Temperature

N/A -40 to 85 ºC

Non-Condensing Relative Humidity

N/A 20 to 80 %

Vibration

N/A IEC 60068-2-6 (sinus-shaped) IEC 60068-2-64 (broadband noise)

Shock Amplitude

N/A 25 g.50 g.

Note for Shock

N/A According to IEC 60068-2-27

Housing Size

N/A 46 x 56 x 66 mm46 x 56 x 77 mm

Note for Housing Size

N/A Depending on lens and focus position

Weight

N/A 237 to 251 g

Optical Resolution

Optical Resolution

N/A 382 x 288 px

Temperature Range

Temperature Range

N/A -20 to 100 ºC0 to 250 ºC150 to 900 ºC

Temperature Range (Option)

N/A 200 to 1500 ºC

Note for Temperature Range

N/A For the range (20)150 up to 900 ºC, the accuracy specification applies from 150 ºC.

Lenses

Lens Field of View (FOV) for f = 20 Millimeter (mm)

N/A 18 x 14 º

Lens Field of View (FOV) for f = 12.7 Millimeter (mm)

N/A 29 x 22 º

Lens Field of View (FOV) for f = 7.7 Millimeter (mm)

N/A 53 x 38 º

Lens Field of View (FOV) for f = 5.7 Millimeter (mm)

N/A 80 x 54 º

Thermal Sensitivity (NETD)

Thermal Sensitivity (NETD) with 29 x 22 Degree Field of View (FOV) for F = 0.9

N/A 40 mK

Thermal Sensitivity (NETD) with 53 x 38 Degree Field of View (FOV) for F = 0.9

N/A 40 mK

Thermal Sensitivity (NETD) with 82 x 54 Degree Field of View (FOV) for F = 0.9

N/A 40 mK

Thermal Sensitivity (NETD) with 18 x 14 Degree Field of View (FOV) for F = 1.1

N/A 60 mK

Note for Thermal Sensitivity (NETD)

N/A Values apply with 40 Hz and 25 ºC room temperature.

Scope of Supply

Scope of Supply

N/A
  • TIM process camera incl. a selectable lens
  • Operating Instructions
  • USB cable 1 m
  • Software for real-time processing and analyzing thermal images
  • Tripod mount
  • PIF cable 1 m
  • Transport case
  • Test Certificate

Software

Software

N/A
  • Display of the thermal image in real time (120 Hz) with recording function (video, snapshot)
  • Complete set up of parameters and remote control of the camera
  • Detailed analysis of fast, thermodynamic processes
  • Output of analog temperature or alarm values via the process interface
  • Digital communication via RS232 or DLL for software integration

Characteristics

Characteristics

N/A
  • Temperature range from -20 ºC to 2450 ºC
  • Compact cameras ideal for OEM applications
  • Up to 1 kHz for fast processes
  • Resolution up to 764 x 480 pixels
  • License-free analysis software and complete SDK included

Software Features

Software Features

N/A Comprehensive IR camera software
  • License-free analysis software and complete SDK included
  • Intuitive user interface
  • Camera remote control via software
  • Displays several camera images in different windows
  • Compatible with Windows 7, 8 and 10
  • Data output via PIF hardware interface using up to 3 analog channels
Video recording and snapshot feature (IR)
  • Recording of video sequences and individual images for later analysis or documentation
  • Adjustable frame rate to reduce data volume
  • Display of snapshot process for direct analysis
Online and offline data analysis
  • Real-time temperature information (ºC or ºF) in main window, as digital display or graphic display
  • Detailed analysis using measuring fields, automatic hotspot/coldspot search
  • Logical linking of temperature information
  • Slow-motion replay without connected camera
  • Various layout functions and color palettes to highlight thermal contrasts
Temperature data analysis and documentation
  • Triggered data collection
  • Radiometric video sequences (*.ravi) and snapshots (*.tiff)
  • Thermal images as *.tiff or *.csv, *.dat text files incl. complete temperature information
  • Data transfer in real time to other software programs via DLL or COM port interfaces

Additional Information

Additional Information

N/A The thermoIMAGER TIM QVGA and TIM 640 cameras are used for stationary thermography tasks where high resolution is required. Due to their high thermal sensitivity, these cameras also detect even the smallest of temperature differences. Both standard lenses and special microscope lenses are available for the TIM QVGA and TIM 640 cameras. The microscope lens enables detailed macro shooting of the smallest of elements. High-resolution macro shooting is possible with a spatial resolution of 28 µm. The distance between the target and the camera varies between 80 mm and 100 mm.
  • Thermal imaging camera with high resolution and sensitivity
  • Detector with 382 x 288 pixels
  • Measuring range from -20 °C to 900 °C (special model up to 1500 ºC)
  • Fast, real-time thermal imager with up to 80 Hz
  • Very high thermal sensitivity with 75 mK (TIM QVGA) and 40 mK (TIM QVGA-HD)
  • Compact design (46 mm x 56 mm x 68 - 77 mm)
  • Lightweight (237 - 251 g, incl. lens)
  • Exchangeable lenses & industrial accessories
  • TIMConnect software delivered with Software Developer Kit
  • 1 Only applies when lens protection tube is used