COMPANY HEADER
Print Back
LVDT sensor with free moveable plunger. The non-contact measurement is completely wear-free. LVDT sensors are primarly used for measurement of movement, displacement and position in vehicles and machines.
Unit of Measure

Specifications

Measuring Range

N/A ±3 mm

Linearity ≤±0.3 % Full Scale Output (FSO)

N/A ≤±18 µm

Linearity ≤±0.15 % Full Scale Output (FSO)

N/A ≤±9 µm

Temperature Stability Full Scale Output (FSO) (Zero)

N/A ≤70 ppm/K

Temperature Stability Full Scale Output (FSO) (Maximum Temperature Error)

N/A ≤150 ppm/K

Sensitivity

N/A 85 mV/mm/V

Excitation Frequency

N/A 5 kHz

Excitation Voltage

N/A 550 mV

Connection

N/A Axial cable outlet Cable diameter of 4.6 mm Integrated cable (3 m) with open ends Minimum bending radius 20 mm (fixed installation)

Storage Temperature

N/A -40 to 80 ºC

Operating Temperature

N/A -20 to 80 ºC

Note for Operation Temperature

N/A Optional up to 200 ºC on request

Pressure Resistance

N/A Atmospheric Pressure

Note for Pressure Resistance

N/A Optional 5 bar or 100 bar on front side on request.

Shock (DIN-EN 60068-2-27)

N/A 100 g40 g6 ms in 3 axes, 1000 shocks each 6 ms in 3 axes, 3 shocks each

Vibration (DIN-EN 60068-2-6)

N/A ±20 g±1.5 mm10 to 58 Hz in 2 axes, 10 cycles each 58 to 500 Hz in 2 axes, 10 cycles each

Protection Class (DIN-EN 60529)

N/A Ingress Protection (IP67) (Plugged)

Housing Material

N/A Stainless Steel

Approximate Weight (Sensors)

N/A 20 g

Approximate Weight (Plunger)

N/A 3 g

Compatibility

N/A MSC7401 MSC7602 MSC7802

Housing length L

N/A 57 mm

Plunger Length

N/A 29 mm

Houing Diameter

N/A 10 mm

Inner Diameter

N/A 2.7 mm

Plunger Diameter

N/A 2 mm

Characteristics

Characteristics

N/A
  • Proven LVDT technology
  • Measuring ranges ±1 … ±25 mm
  • Extremely accurate also under difficult ambient conditions
  • Long-term stability
  • Robust design IP67

Application

Application

N/A The DTA displacement sensors are suitable for numerous measurement tasks which require robust designs and high signal stability. Due to their wear-free design, the DTA sensors impress with longevity and long-term stability

Additional Information

N/A LVDT displacement sensors have a plunger which moves freely in the sensor housing. The plunger is joined to the object by a thread to transfer the movement of the measuring object. The measurement process in the sensor takes place without contact and is therefore wear-free.

The displacement sensors are primarily used to measure and monitor movements, displacements, positions, strokes, deflections, dislocations, etc. in vehicles, machines and systems.

The high sensor resolution is only limited by the noise of the sensor controller. Another advantage of the symmetric LVDT sensors is their zero point stability. The sensors are supplied with an excitation frequency of 1 to 5 kHz depending on the measuring range and an excitation voltage of 0.4Veff. Adapted sensor controllers are available for this purpose.

With appropriate setting possibilities for the excitation frequency and excitation voltage, the sensors can also be operated with alternative controllers