Resolution |
N/A 0.25 mm |
Measuring Range |
N/A 500 mm |
Frequency Response at -3 Decibel (dB) |
N/A 150 Hz |
Measuring Rate |
N/A 600 Sa/s |
Linearity ≤±0.23 % Full Scale Output (FSO) |
N/A ≤±1.5 mm |
Temperature Stability Full Scale Output (FSO) |
N/A ≤200 ppm/K |
Direct Current (DC) Supply Voltage |
N/A 18 to 30 V |
Maximum Current Consumption |
N/A 40 mA |
Analog Output Current |
N/A 4 to 20 mA |
Note for Analog Output |
N/A Optional voltage output (1 … 5 V) with output cable C703-5/U for EDS. |
Analog Output Load Resistance |
N/A 500 O |
Connection |
N/A 7-pin M9 screw/plug connection (Binder); axial, radial on request. Bayonet 5-pin screw/plug connection; radial output. |
Storage Temperature |
N/A -40 to 100 ºC |
Operating Temperature |
N/A -40 to 85 ºC |
Pressure Resistance (Front) |
N/A 450 bar |
Shock (DIN-EN 60068-2-27) |
N/A 100 g/6 ms radial, 3 shocks each 300 g/6 ms axial, 3 shocks each 40 g/6 ms in 3 axes, 1000 shocks each |
Vibration (DIN-EN 60068-2-6) |
N/A ±2.5 mm/5 to 44 Hz, 10 cycles each ±23 g/44 to 500 Hz, 10 cycles each |
Protection Class (DIN-EN 60529) |
N/A Ingress Protection (IP67) |
Note for Protection Class (DIN-EN 60529) |
N/A Models with plug connection only with suitable and connected mating plug. |
Housing Material |
N/A Stainless Steel |
Measuring Tube Material |
N/A Aluminum |
Dimenison L |
N/A 550 mm |
Dimenison d |
N/A 12 mm |
Dimenison I |
N/A 550 mm |
Dimenison (d) |
N/A 18 mm |
Dimenison (a) |
N/A 25 mm |
Characteristics |
N/A
|
N/A
induSENSOR EDS long-stroke sensors are designed for industrial use in hydraulic and pneumatic cylinders for displacement and position measurements of pistons or valves, e.g., to measure |