COMPANY HEADER
Print Back
Unit of Measure

Z-Axis (Height)

Standard Start of Measuring Range (50 Millimeter (mm))

N/A 70 mm

Standard Measuring Midrange (50 Millimeter (mm))

N/A 95 mm

Standard End of Measuring Range (50 Millimeter (mm))

N/A 120 mm

Extended Start of Measuring Range (60 Millimeter (mm))

N/A 65 mm

Extended End of Measuring Range (60 Millimeter (mm))

N/A 125 mm
Linearity (3 Sigma) Full Scale Output (FSO)1 N/A ±0.10 %
Reference Resolution2 N/A 4 µm

X-Axis (Width)

Standard Start of Measuring Range

N/A 42 mm

Standard Measuring Midrange

N/A 50 mm

Standard End of Measuring Range

N/A 58 mm

Extended Start of Measuring Range

N/A 40 mm

Extended End of Measuring Range

N/A 60 mm

Resolution - (X-Axis (Length))

N/A 1280 points/profile 640 points/profile

Specifications

Profile Frequency

N/A 2000 Hz

Measurement Rate

N/A 2.56 Mio. points/sec
Ethernet GigE-Vision Interfaces3 N/A Measurement Values Profile Data Sensor Configuration

Digital Inputs Multi Function Port Interfaces

N/A Encoder Mode Switching Trigger

RS422 (Half-Duplex) Multi Function Port Interfaces

N/A Output of Measurement Values (Output of measurement values only with SMART sensors via Modbus RTU or ASCII data) Sensor Control Synchronization Trigger

Display (Light Emitting Diode (LED))

N/A 1x laser ON/OFF 1x power/error/status

Light Source

N/A Semiconductor Laser 405 nm

Aperture Angle Laser Line

N/A 25 º

Laser Power (2M Laser Class)

N/A 8 mW

Laser Off

N/A Via External Contact (optional)
Permissible Ambient Light (Fluorescent Light)4 N/A 10,000 lux

Protection Class

N/A Ingress Protection (IP65)

EMC

N/A acc. EN 61326-1: 2006-10 DIN EN 55011: 2007-11 (group 1, class B) EN 61000-6-2: 2006-03

Operating Temperature

N/A 0 to 45 ºC

Storage Temperature

N/A -20 to 70 ºC

Dimensions

N/A 96 x 85 x 33 mm

Sensor Weight

N/A 380 g

Direct Current (DC) Supply Voltage

N/A 11 to 30 V24 V

Current

N/A 500 mA

Industry Standards - Supply

N/A IEEE 802.3af class 2, Power over Ethernet

Classes

N/A High Speed

Vibration

Vibration Amplitude

N/A 2 g.

Vibration Frequency Range

N/A 20 to 500 Hz

Shock

Shock Amplitude

N/A 15 g.

Shock Duration

N/A 6 ms

Note

N/A For Reference resolution

Measuring object: Micro-Epsilon standard object (metallic, diffusely reflecting material)
According to a one-time averaging across the measuring field (640 points)

  • 1 Standard measuring range
  • 2 Measuring object: Micro-Epsilon standard object (metallic, diffusely reflecting material)
    According to a one-time averaging across the measuring field (640 points)
  • 3 Output of measurement values only with SMART sensors via Modbus TCP or switching signals/analogue outputs (only with Output Unit)
  • 4 Measuring object: Micro-Epsilon standard object (metallic, diffusely reflecting material)