COMPANY HEADER
Print Back
Thermal imaging camera with line scan feature for the glass industry
  • Line scan feature via license-free TIMConnect analysis software
  • Compact size of 46 x 56 x 90 mm
  • Frame rate up to 125 Hz
  • Robust against ambient temperatures up to 70 ºC without requiring additional cooling, up to 315 ºC with cooling jacket
  • Optional integration of a reference pyrometer for glass with a reflection coating
  • Compact design (46 x 56 x 90 mm) with USB interface
  • Lightweight (320 g incl. lens)
  • Exchangeable lenses & industrial accessories
  • Software TIMConnect included
  • Software Developer Kit and LabVIEW examples included
Unit of Measure

Specifications

Optical Resolution

N/A 382 x 288 px

Temperature Range

N/A 200 to 1500 ºC

Sighting

N/A 0 to 250 ºC

Spectral Range

N/A 7.9 µm
System Accuracy1 N/A ±2 ºC or ±2 %, Whichever is Greater

Thermal Sensitivity (NETD)

N/A 130 mK

Detector

N/A Focal Plane Array (FPA), Uncooled (25 x 25 µm)

Digital Output

N/A Optional GigE USB 2.0

Standard Process Interface (PIF)

N/A 0 to 10 V Input 0 to 10 V Output Digital Input (Maximum 24 V)

Standard Universal Serial Bus (USB) Cable Length

N/A 1 m
Universal Serial Bus (USB) Cable Length2 N/A 10 m5 m

Power Supply

N/A USB Powered

Tripod Mount

N/A 1/4 in. - 20 UNC

Protection Class

N/A Ingress Protection (IP67)

Ambient Temperature

N/A 0 to 70 ºC

Switchable Frame Rate

N/A 27 Hz80 Hz

Storage Temperature

N/A -40 to 85 ºC

Non-Condensing Relative Humidity

N/A 20 to 80 %

Vibration

N/A IEC 60068-2-6 (sinus-shaped) IEC 60068-2-64 (broadband noise)

Shock Amplitude

N/A 25 g.50 g.

Note for Shock

N/A According to IEC 60068-2-27

Industry Process Interface (PIF)

N/A 2x 0 to 10 V Input 3x 0(4) - 20 mA outputs 3x Relays (0 - 30V/ 400mA) Digital Input (Maximum 24 V) Fail Safe Relay

Housing Size

N/A 46 x 56 x 90 mm

Weight Including Lens

N/A 320 g

PC Requirements

N/A 1 GB RAM Minimum 1.5 GHz Windows 7 Windows XP SP 2

Lenses

Lens Field of View (FOV) for f = 41 Millimeter (mm)

N/A 13 x 10 º

Lens Field of View (FOV) for f = 18.7 Millimeter (mm)

N/A 29 x 22 º

Lens Field of View (FOV) for f = 10.5 Millimeter (mm)

N/A 53 x 40 º

Lens Field of View (FOV) for f = 7.7 Millimeter (mm)

N/A 80 x 56 º

Note for Lens Field of View (FOV)

N/A Measurement accuracy can be out of specification with distances below 200 mm

Scope of Supply

Scope of Supply

N/A
  • TIM process camera incl. a selectable lens
  • Instruction Manual
  • USB cable 1 m
  • Software for real-time processing and analyzing thermal images
  • Tripod mount
  • PIF cable incl. terminal block (1 m)
  • Transport case

Software

Software

N/A
  • Line scan feature
  • Display of the thermal image in real time (80 Hz) with recording function (video, snapshot)
  • Complete set up of parameters and remote control of the camera
  • Detailed analysis of fast, thermodynamic processes
  • Output of analog temperature or alarm values via the process interface
  • Digital communication via RS232 or DLL for software integration
  • 1 Whichever is greater.
  • 2 5 m and 10 m also as high temperature USB cable (180 ºC).