Measuring Range |
N/A 10 mm |
Operating Gap |
N/A 46 mm |
Measuring Width |
N/A 200 mm |
Combined Linearity Tolerance (±) |
N/A 10 µm |
Measuring Rate |
N/A 0.25 kHz0.5 kHz1 kHz2 kHz4 kHz |
Light Source - Semiconductor Laser Wavelength |
N/A 670 nm<1 mW |
Light Source Color |
N/A Red |
Permissible Ambient Light |
N/A 10,000 lux |
Maximum Light Spot Diameter |
N/A 140 x 160 µm |
Maximum Light Spot Diameter Tolerance (±) |
N/A 10 % |
Protection Class |
N/A Ingress Protection (IP65) |
Laser Safety Class |
N/A Class 2 According to DIN EN 60825-1 : 2008-05 |
Temperature Stability Full Scale Output (FSO) |
N/A ±0.03 %/°C |
Non-Condensing Operating Temperature |
N/A 0 to +50 ºC |
Non-Condensing Storage Temperature |
N/A -20 to +70 ºC |
Control Input/Output (I/O) |
N/A 1x Master 1x Trigger in 2x Switching Outputs |
Analog Measurement Output Voltage |
N/A 0 to 5 V0 to 10 V |
Analog Measurement Output Voltage Tolerance (±) |
N/A 5 V10 V |
Analog Measurement Output Current |
N/A 4 to 20 mA |
Digital Measurement Output |
N/A Ethernet |
Weight |
N/A 2.8 kg |
Display Sensor |
N/A 3x color LEDs for power and status |
Controller Display |
N/A Power Input/Output (I/O) |
Web Interface Operation |
N/A Data Reduction Limit Values Selectable Averaging Possibilities Setup Management |
Power Supply for 24 Volt (V) Voltage |
N/A <5 W |
Direct Current (DC) Power Supply |
N/A 11 to 30 V |
Electronics |
N/A Integrated Signal Processor Signal Processing Unit |
Electromagnetic Compatibility (EMC) Requirements |
N/A DIN EN 61326-1 DIN EN 61326-1 (class B) EN 61 000-6-2 EN 61 000-6-3 |
Features |
N/A
|
Additional Information |
N/A
Compact design and high precision The thicknessSENSOR enables turnkey thickness measurement along with an unmatched price/performance ratio. Due to its extremely compact design, this sensor system can also be integrated in a confined installation space. The two sensors are perfectly adjusted to each other in terms of their mounting conditions, therefore providing high measurement accuracy. Using a calibration target, the sensors can be calibrated at any time. Unique ease of use The thicknessSENSOR is operated using an intuitive web interface. The settings for the measurement task can be quickly selected using predefined presets. Different configuration and set up possibilities enable the user to easily adapt the sensor e.g. to dynamic measurements. Up to eight user-specific sensor settings can be stored and exported in the setup management. The signal peak selection and a freely adjustable signal averaging enable the experienced user to optimize the measurement task. |